To work around this problem, increase the time-out value of request execution.
You can do that by following two ways:
Method 1:
EAUpload component provides a replacement of
executionTimeout attribute of httpRuntime config section.
If ExecutionTimeout parameter of EAUpload
environment is defined then request have time-out that
is specified by this parameter and "executionTimeout"
parameter of httpRuntime configuration section is ignored.
The specified value will take effect only for requests which
are processed by EAUpload component. The value that is
specified in executionTimeout attribute will be actually for other requests.
Set the ExecutionTimeout parameter value in the EAUpload configuration
- Open the Web.config file in Notepad.
- Increase the value of the ExecutionTimeout attribute to avoid time-out errors.
<?xml version="1.0" encoding="utf-8" ?>
<configuration>
...
<EasyAlgo.EAUpload>
<Environment
...
ExecutionTimeout="3600"
...
/>
<ErrorsProcessing
...
/>
</EasyAlgo.EAUpload>
...
</configuration>
- Save the Web.config file.
Method 2:
The executionTimeout attribute exists under httpRequest in
the Machine.config file. You can change these settings either
in the Web.Config file or in the Machine.config file.
The default value for the time-out is 90 seconds.
The executionTimeout attribute indicates the maximum
number of seconds a request is permitted to run before
being shut down by the ASP.NET Web application.
Figure A: Set the executionTimeout attribute value in the Web.config File
- Open the Web.config file in Notepad.
- Add the httpRuntime element in the system.web section as follows:
<?xml version="1.0" encoding="utf-8" ?>
<configuration>
...
<system.web>
<httpRuntime executionTimeout="90" maxRequestLength="4096"
useFullyQualifiedRedirectUrl="false"
minFreeThreads="8"
minLocalRequestFreeThreads="4"
appRequestQueueLimit="100" />
</system.web>
...
</configuration>
- Increase the value of the executionTimeout attribute to avoid time-out errors.
- Save the Web.config file.
Figure B: the executionTimeout attribute value in the Machine.config File
- Open the Machine.config file in Notepad. The Machine.config file
is located in the %SystemRoot%\Microsoft.NET\Framework\%VersionNumber%\CONFIG\ directory.
- In the Machine.config file, locate the httpRuntime element.
<httpRuntime executionTimeout="90" maxRequestLength="4096"
useFullyQualifiedRedirectUrl="false"
minFreeThreads="8"
minLocalRequestFreeThreads="4"
appRequestQueueLimit="100" />
- Increase the value of the executionTimeout attribute to avoid time-out errors.